↑ Return to GR4J daily model

Description of the GR4J model

The GR4J model has four parameters to optimise during calibration:

  • X1 : the production store maximal capacity (mm),
  • X2 : the catchment water exchange coefficient (mm),
  • X3 : the one-day maximal capacity of the routing reservoir (mm),
  • X4 : the HU1 unit hydrograph time base (days).

We denote by P (mm) the rainfall amount and by E (mm) the potential evapotranspiration (PET). P is an estimation of the catchment rainfall and E can come from a mean interannual PET curve.

The following equations correspond to the equations integrated over a time step.

The first operation is the neutralization of P by E to determine a net rainfall Pn and a net evapotranspiration En, calculated by:

If P > E, then Pn = PE and En = 0

If P < E, then Pn = 0 and En = EP

In case Pn is different from zero, a fraction Ps of Pn goes to the production reservoir and is calculated by:

where X1 (mm) and S are, respectively, the maximum capacity and the production store level.

Otherwise, when En is différent from zero, a part of evaporation Es is removed from the production store. It is given by:

The production store level is updated through:

S = SEs + Ps

A percolation called Perc coming from the production store is then calculated:

The production store level is then again updated:

S = S – Perc

The water quantity Pr that finally reaches the routing part of the model is:

Pr = Perc + (Pn – Ps)

Pr is divided into two flow components, 90 % being routed by a unit hydrograph HU1 and a routing store and 10 % by a unic unit hydrograph HU2.

HU1 and HU2 depend on the same parameter X4, the time base of HU1 expressed in days.

The hydrograms ordinates are calculated from the S curves (the accumulation of the proportion of unit rainfall treated by the hydrogram in function of time), respectively named SH1 and SH2.

SH1 is defined in function of time by:

For t = 0

For 0 < t < X4

For t > X4

SH2 is defined in function of time by:

For t = 0

For 0 < t < X4

For X4 < t < 2X4

For t > 2X4

The ordinates of HU1 and HU2 are then obtained from:

where j is an integer.

For each time step i, the outputs Q9 and Q1 of the two hydrograms are calculated with:

with l = int(X4)+1 and m = int(2.X4)+1, with int(.) the integer part.

A groundwater exchange term (loss or gain) is calculated with:

with R the routing store level, X3 the one-day maximal capacity of the store and X2 the water exchange coefficient, which is positive in case of a gain, and negative in case of a loss, or null.

The level in the routing store is updated by adding the Q9 output of the hydrogram HU1 and F:

R = max (0 ; R + Q9 + F)

Then, it empties in an output Qr given by:

The level in the store becomes: R = RQr

The output Q1 of the hydrogram HU2 goes through the same exchanges to give the flow component Qd:

Qd = max (0 ; Q1+F)

The total streamflow Q is finally given by: Q = Qr + Qd

To know more: check our publications.

The GR4J code in Excel.

The GR4J code in R.